Measuring that the pp_vbus1_e75 of U3300 has 5V when the motherboard is disassembled, and the battery holder has no voltage, so it is preliminarily judged that the charging IC U3300 is broken. Cooling installation test, charging is normal, troubleshooting, and maintenance is over.