The measured capacitance of corrosion at startup is 1.8V, and the measured capacitance is 2.4V This circuit is connected to the signal chip of the main board, the upper board and the tail plug-in board. Redo this chip, and the power-on test voltage is restored to 1.8V. Boot test, perfect repair.