The iPhone6 Plus screen does not display, the detection is found to be inductively broken, and then replace the chip again, power-on troubleshooting.
The iPhone 6s boot white apple restarts, and the detection is found to be caused by the damage to the U5411_RF chip, and the problem is repaired.
Honor 30 Pro auto restart mobile phone no serviecs, detection found Inductor Inveracious Soldering caused, after replacement, the boot is normal.
The elegant HP640 notebook in China doesn't respond when it is turned on, but the memory,Reballing North Bridge chip and 2 Capacitor are turned on normally.
After the iPhone7 is turned on, it enters the system screen and shows that the waves are moving. This machine is Previously repaired. After replacing the integrated Inductor, the screen display is normal.
iPhone6 Plus expansion causes the brush to fail, replace the new hard drive, replenish the capacitance around the hard disk, repair and repair.
ViVO Y93 mobile phone indicates that the temperature is too low to charge, and it is found that the 20th pin of the sub-board BTB connector is disconnected, and the fault is repaired after Jump wire.
MacBook Pro A1502 notebook water cannot be turned on, the motherboard is blurred, no sound, the master fly directly.
The iPhone 6 mobile phone SIM cannot be read. It is detected that the baseband is broken, and the final machine cannot be repaired.