iPhone 6s mobile phone inlet is unable to turn on, and the component is directly replaced by the backlight.
iPhone 6 Plus phone has no signal, * # 06 # no serial number, detected is caused by the U_MBPAD intensive pad drop-off point, and the fill point is loaded.
The iPhone X mobile phone has no service, and the detection is caused by the corruption of RF IC, and the fault restoration is replaced.
iPhone 6s mobile phone touchs the failure, the touch related to the touch is excluded, the screen is also replaced, and finally the R3144 should be empty. The pad is shorted, and the fault repair is fixed after disconnection.
The iPhone 6 Plus black screen can't open, and it is detected that the three VDD10_MIPIC Point short circuits on the CPU are caused, directly on the green oil, and the fault is perfect.
iPhone 6 screen failure, after the test, the problem is replaced, and the problem is repaired.
iPhone 6 power supply failure caused DFU mode to fail to exit, so it was repaired after the main power supply was restored.
The iPhone 6s black screen does not respond, and the test is found to be caused by backlight booster inductance, and after replacement, the problem is repaired.
iPhone 6 Plus Front Camera does not work and the distance sensing cannot be used. It is found that it is caused by the small component Inveracious Soldering, and the problem is repaired after short-circuit.
iPhone X fell to no serviecs, and after detection, it was found that this fault was caused by middle pad break off, and Jump wire repaired the fault after repairing points.